INTEG Process Group, Inc.
JNIOR
A Network I/O Resource 42
Cinema.JNIOR Application Manual
8 Fire Alarm
The Cinema.JNIOR Application can handle a variety of fire alarm issues. The following
Fire Alarm features can be configured.
NOTE: The following Registry keys appear in various screen shots previously included
in this document.
Fire Alarm Input
This is the input that is assigned to the fire alarm signal. The default JNIOR settings will
work with an input that is normally low (off) and goes high (on) when the fire alarm is
tripped. The JNIOR can also be configured to work with a fire alarm that has a normally
high (on) signal that goes low (off) when the fire alarm is tripped. For the latter, the fire
alarm input must be set for ‘inversion’. This can be done via the main JNIOR web page
or a Telnet session. The registry key and value to set so that the input is configured for
inversion is ‘IO/Inputs/dinX/Inversion = true’ where you replace X with the appropriate
input number.
Registry Key Default Valid Values
AppData/Cinema/IO/FireAlarmInput 1 -1 or Any Input
Number 1- 8
Fire Alarm Release Input
This is the input that is assigned to the fire alarm release signal. Since the fire alarm
signal may not stay high (on) or low (off) for the entire duration of the fire alarm event
there needs to be a signal indicating ‘all clear’.
Registry Key Default Valid Values
AppData/Cinema/IO/FireAlarmReleaseInput 2 -1 or Any Input
Number 1- 8
Fire Alarm Active Text
This is the text that will be sent in the SNMP message on a fire alarm event.
Registry Key Default Valid Values
AppData/Cinema/FireAlarmActiveText Fire Alarm Active
Any Text