INTEG Process Group, Inc.
JNIOR
A Network I/O Resource 40
Cinema.JNIOR Application Manual
There are 4 logic categories.
1. OnIOChange
This logic expression will be checked whenever the JNIOR I/O changes. The I/O
that can be monitored are the internal inputs and outputs on the JNIOR as well as
any outputs on a 4 relay output expansion module.
Example Registry Key Value
OnIOChange, din1 and din2, run test
For the above example, each time either input 1 or 2 changes, the logic rule (din1
AND din2) will be evaluated and the macro (test) will execute if both inputs are
ON.
2. OnPreshowClient()
This logic expression will be checked whenever the Preshow Client in
Cinema.JNIOR receives a message. To specify the string/message that will cause
the logic to be evaluated put it inside the parenthesis.
Example Registry Key Value
OnPreshowClient(start), din3 and din4, run preshow start
For the above example, each time the device connected to the JNIOR as the
Preshow Client sends the string “start” to Cinema.JNIOR, the logic rule (din3
AND din4) will be evaluated and the macro (preshow start) will execute if both
inputs are ON.
3. OnCinemaServer()
This logic expression will be checked whenever the Cinema Server Client in
Cinema.JNIOR receives a message. To specify the string/message that will cause
the logic to be evaluated put it inside the parenthesis.
Example Registry Key Value
OnCinemaServer(movie), din5 or din6, run movie start
For the above example, each time the device connected to the JNIOR as the
Cinema Server Client sends the string “movie”, the logic (din5 OR din6) will be
evaluated and the macro (movie start) will be run if either digital input is ON.