The JSD-60 holds a log of the last 15,000 events. Events include level changes, format changes, remote connections
by the GUI or other devices, etc. Press the Get Latest button to get the 100 most recent log entries. Press the Get
All button to get the full log from the JSD-60.
The log shows the record number in the JSD-60 log, the UTC time of the event, the “JSD Time” of the event, and
the “GUI Time” of the event. The JSD-60 stores all log events in UTC time. When the log events are displayed by
the GUI, the time at the JSD-60 is calculated based on the settings entered using the “Date & Time” button on the
Global Tab. The GUI applies the time zone offset for where the JSD-60 is located, determines if the daylight saving
time is observed where the JSD-60 is located, and whether daylight saving time is currently in effect. Based on this
data, the GUI calculates and displays the time of the event at the JSD-60. The name of the time zone (PDT in the
sample) is shown in the column header to help identify the time. The GUI also does a similar calculation to display
“GUI time” or local time for the computer running the GUI application. That is the time the event occurred at the
GUI location, which may be several time zones away from where the JSD-60 is located. The log shows the source of
the event (internal, USB Port, front panel, TCP4, etc.). When a device connects to the JSD-60 over Ethernet, the
connection and the IP address are logged. Later actions can be tied to a specific IP address by looking back
through the log for the last connection to that TCP port. The JSD-60 supports 5 simultaneous TCP connections on
TCP4 through TCP0.
Pressing the Save button saves the currently displayed log data as a tab delimited text file. This file can be
imported into a spreadsheet or viewed with a text editor.
7.10.9 Diagnostics Tab
This tab provides diagnostics that help USL personnel in debugging the system. You may be instructed by USL to
perform various functions on this tab to debug problems in the installation. The terminal section of this screen can
be used to test JSD-60 commands, such as ones an automation system can send. Click the mouse cursor in the
terminal area, and then type commands (tab delimited and terminated with a carriage return). See Appendix B for
more information on automation commands.
7.11 Channel Crossover and Equalization Procedure
Audio channel equalization consists of two steps:
1. Crossover adjustment (if crossovers used).
2. Channel Equalization.
7.11.1 Crossover Adjustment
A suggested crossover adjustment procedure is listed below. It should be skipped if the JSD-60 internal crossovers
are not being used. If an external pink noise generator is to be used with the internal RTA, enable the internal pink
Vue de la page 37